Horizontal Cylindrical Autoclave
Horizontal Cylindrical Autoclave Specification
- Type
- Horizontal Cylindrical
- Chamber Size
- 1200/1500/1800 mm L × 600/750 mm Dia
- Chamber Thickness
- 8 to 10 mm (Stainless Steel Grade 316)
- Outer Size
- 1700 x 700 x 900 mm (Approx)
- Compressed Air
- 6-8 Bar Required
- Door Type
- Radial Locking, Manual / Motorized
- Design Pressure
- 2.5 kg/cm²
- Working Pressure
- 1.2 to 1.5 kg/cm²
- Design Temperature
- Up to 140°C
- Heat Uniform
- ± 1°C (Uniformity Maintained)
- Insulation
- High Density Glass Wool
- Net Weight
- Approx 550 kg
- Recording Parameters
- Digital Temperature & Pressure Recorder
- Spraying Mode
- Pulsating Spray or Uniform Spray via Nozzles
- Outer Trolley
- Stainless Steel Fabricated, Removable
- Inner Trolley
- Stainless Steel with Perforated Shelves
- Spraying Piping
- SS-316, Inbuilt for Direct Steam & Water Access
- Steam
- External / Internal Steam Generator, 380V, 3 Phase
- Sterilizing Temperature
- 121°C (Standard), Adjustable
- Working Temperature
- 121°C / 134°C
- Sterilization Time
- 15-60 Minutes, Programmable
- Temperature Scope
- Adjustable from Ambient to 134°C
- Piping System
- High-Pressure SS-316 Tubing
- Valves
- Pressure Relief, Safety, Steam Trap, Manual & Auto
- Power Consumption
- 6 - 18 kW (Model Dependent)
- Electrical Supply
- 380V, 50Hz, 3 Phase
- Accessories
- Spare Gaskets, Trolley Handles, Data Logger
- Exterior Finish
- Matte / Glossy Polished Stainless Steel
- Water Drainage
- Auto & Manual Drain Valves with Filters
- Mounting Type
- Floor Mounted with Adjustable Feet
- Chamber Material
- Stainless Steel 316/304 (Mirror Finish)
- Control System
- Automatic PLC Based with HMI Touch Screen
- Gasket Material
- Silicon / EPDM Steam Resistant
- Safety Interlocks
- Pressure, Temperature, Door Locking
- Heater Elements
- Heavy Duty, Low Watt Density, ISI Marked

More Products in Autoclaves And Sterilizers Category
Vertical Autoclave
Working Temperature : Up to 134°C
Working Pressure : 0.22 MPa
Chamber Size : 430 mm x 300 mm (Dia x Depth)
Sterilizing Temperature : 121°C
Temperature Scope : 105°C – 134°C
Recording Parameters : Digital temperature and time display
Table Top Autoclave
Working Temperature : 121°C / 134°C
Working Pressure : 1.2 bar
Chamber Size : 300 mm x 500 mm (Dia x Depth)
Sterilizing Temperature : 121°C
Temperature Scope : 105°C to 134°C
Recording Parameters : Digital Display, Manual Recording
Instrument Sterilizer
Working Temperature : 121°C
Working Pressure : 1 MPa
Chamber Size : Medium 300mm x 450mm
Sterilizing Temperature : 121°C
Temperature Scope : Ambient to 135°C
Recording Parameters : None
Filter Holder And Sterlity Test Unit
Working Temperature : Maximum 121°C
Working Pressure : 0.10.2 MPa (operating range)
Chamber Size : Filter chamber: fits standard 47 mm or 50 mm membrane
Sterilizing Temperature : 121°C (autoclavable components)
Temperature Scope : Room temperature to 121°C
Recording Parameters : Manual or external documentation (no builtin recorder)

Send Inquiry