Vertical Autoclave - Single Lever
Vertical Autoclave - Single Lever

Vertical Autoclave - Single Lever

Vertical Autoclave - Single Lever Specification

  • Type
  • Vertical Autoclave, Floor Standing, Single Lever Locking.
  • Chamber Size
  • Standard options: 22L, 30L, 50L, 75L, 100L (Custom sizes on request).
  • Chamber Thickness
  • 4–6 mm heavy gauge SS chamber sheet.
  • Outer Size
  • As per standard laboratory sizes; typically custom sizes available on request.
  • Compressed Air
  • Not required; single lever locking mechanism eliminates need for compressed air.
  • Door Type
  • Single lever, vertical closing door, spring-loaded locking system for safety.
  • Design Pressure
  • 2.2 kg/cm² or higher as per industry standard.
  • Working Pressure
  • 1.2 to 1.5 kg/cm².
  • Design Temperature
  • 134°C maximum.
  • Heat Uniform
  • Uniform chamber heating by steam jacket.
  • Insulation
  • Glass wool thermal insulation, double-walled construction.
  • Net Weight
  • Approx. 80–150 kg depending on chamber size.
  • Recording Parameters
  • Digital display with cycle progress, temperature and pressure record.
  • Spraying Mode
  • Uniform steam distribution via inbuilt piping.
  • Outer Trolley
  • Optional stainless steel trolley for easy mobility.
  • Inner Trolley
  • Removable stainless steel basket/trolley for chamber loading.
  • Spraying Piping
  • Stainless steel inbuilt steam distribution pipework.
  • Steam
  • Saturated steam generated internally or by external boiler.
  • Sterilizing Temperature
  • 121°C to 134°C adjustable.
  • Working Temperature
  • Up to 134°C.
  • Sterilization Time
  • 0 to 99 minutes programmable cycle.
  • Temperature Scope
  • Ambient to 134°C.
  • Piping System
  • Corrosion resistant SS 304/SS 316 grade piping.
  • Valves
  • Safety valve, Pressure relief valve, Steam release valve.
  • Power Consumption
  • 2.5 kW to 6 kW depending on model.
  • External Finish
  • Matte/brushed stainless finish; corrosion-resistant.
  • Water Level Sensor
  • Automatic water level cut-off system.
  • Control Panel
  • Microprocessor-based programmable control with timer and alarm.
  • Display Type
  • Digital PID temperature controller, LED display.
  • Installation
  • Floor standing with optional wheel-mounted base.
  • Application
  • Suitable for laboratory, medical, pharmaceutical, and research institutes.
  • Pressure Gauge
  • Analog and digital pressure gauge for monitoring.
  • Accessories
  • Standard with perforated baskets and water draining port.
  • Power Supply
  • 230V AC, 50 Hz (single phase); also available in 440V 3-phase.
  • Material of Construction
  • Stainless Steel SS 304/SS 316 grade both inner and outer chamber.
  • Safety Features
  • Door safety interlock, over-temperature and over-pressure protection.
  • Heating Element
  • ISI marked tubular immersion heaters; replaceable type.
  • Calibration
  • Calibrated for temperature and pressure accuracy.
 
 

More Products in Autoclaves And Sterilizers Category

Vertical Autoclave

Vertical Autoclave

Type : Other, Vertical cylindrical

Outer Size : 600 mm x 400 mm

Net Weight : Approx. 65 kg

Door Type : Manual lid with radial locking system

Insulation : Double wall with glass wool insulation

Design Pressure : 0.25 MPa

Table Top Autoclave

Table Top Autoclave

Type : Other, Fully Automatic Table Top

Outer Size : 510 x 410 x 370 mm

Net Weight : 38 kg

Door Type : Single, Manual Swing Door with Safety Lock

Insulation : Highdensity Mineral Wool

Design Pressure : 2.2 bar

Filter Holder And Sterlity Test Unit

Filter Holder And Sterlity Test Unit

Type : Other, Filter Holder & Sterility Test Unit

Outer Size : 240 x 190 x 50 mm (approx.)

Net Weight : Approx. 23 kg

Door Type : Clamp type lid with silicone gasket for airtight seal

Insulation : Not required (handheld unit)

Design Pressure : 0.25 MPa max

Cooker Type Portable Autoclave

Cooker Type Portable Autoclave

Type : Other, Portable Autoclave Cooker Type

Outer Size : 305mm x 305mm x 500mm

Net Weight : Approx. 14 kg

Door Type : Cooker Type Lid with Locking System

Insulation : Double Wall Construction for Heat Retention

Design Pressure : 2.2 kg/cm²



Get in touch with us
RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com